CVE-ID

CVE-2019-19015

• CVSS Severity Rating • Fix Information • Vulnerable Software Versions • SCAP Mappings • CPE Information
Description
An issue was discovered in TitanHQ WebTitan before 5.18. The proxy service (which is typically exposed to all users) allows connections to the internal PostgreSQL database of the appliance. By connecting to the database through the proxy (without password authentication), an attacker is able to fully control the appliance database. Through this, several different paths exist to gain further access, or execute code.
References
Note: References are provided for the convenience of the reader to help distinguish between vulnerabilities. The list is not intended to be complete.
Assigning CNA
MITRE Corporation
Date Record Created
20191117 Disclaimer: The record creation date may reflect when the CVE ID was allocated or reserved, and does not necessarily indicate when this vulnerability was discovered, shared with the affected vendor, publicly disclosed, or updated in CVE.
Phase (Legacy)
Assigned (20191117)
Votes (Legacy)
Comments (Legacy)
Proposed (Legacy)
N/A
This is an record on the CVE List, which provides common identifiers for publicly known cybersecurity vulnerabilities.