Description |
The flowd process, responsible for forwarding traffic in SRX Series services gateways, may crash and restart when processing specific transit IP packets through an IPSec tunnel. Continued processing of these packets may result in an extended Denial of Service (DoS) condition. This issue only occurs when IPSec tunnels are configured. Systems without IPSec tunnel configurations are not vulnerable to this issue. This issue affects Juniper Networks Junos OS: 15.1X49 versions prior to 15.1X49-D171, 15.1X49-D180 on SRX Series; 18.2 versions 18.2R2-S1 and later, prior to 18.2R3 on SRX Series; 18.4 versions prior to 18.4R2 on SRX Series.
|
References |
Note: References are provided for the convenience of the reader to help distinguish between vulnerabilities. The list is not intended to be complete.
|
|
Assigning CNA |
Juniper Networks, Inc. |
Date Record Created |
20181011 |