CVE-ID

CVE-2025-22961

• CVSS Severity Rating • Fix Information • Vulnerable Software Versions • SCAP Mappings • CPE Information
Description
A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.
References
Note: References are provided for the convenience of the reader to help distinguish between vulnerabilities. The list is not intended to be complete.
Assigning CNA
MITRE Corporation
Date Record Created
20250109 Disclaimer: The record creation date may reflect when the CVE ID was allocated or reserved, and does not necessarily indicate when this vulnerability was discovered, shared with the affected vendor, publicly disclosed, or updated in CVE.
Phase (Legacy)
Assigned (20250109)
Votes (Legacy)
Comments (Legacy)
Proposed (Legacy)
N/A
This is an record on the CVE List, which provides common identifiers for publicly known cybersecurity vulnerabilities.