Search Results

There are 1028 CVE Records that match your search.
Name Description
CVE-2024-3910 A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3909 A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3908 A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3907 A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3906 A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3905 A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3882 A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3881 A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3880 A vulnerability has been found in Tenda W30E 1.0.1.25(633) and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260914 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3879 A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3878 A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3877 A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3876 A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3875 A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3874 A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-32320 Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function.
CVE-2024-32318 Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function.
CVE-2024-32317 Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2024-32316 Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function.
CVE-2024-32315 Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2024-32314 Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
CVE-2024-32313 Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the adslPwd parameter of the formWanParameterSetting function.
CVE-2024-32312 Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function.
CVE-2024-32311 Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2024-32310 Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function.
CVE-2024-32307 Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
CVE-2024-32306 Tenda AC10U v1.0 Firmware v15.03.06.49 has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
CVE-2024-32305 Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
CVE-2024-32303 Tenda AC15 v15.03.20_multi, v15.03.05.19, and v15.03.05.18 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
CVE-2024-32302 Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.
CVE-2024-32301 Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.
CVE-2024-32299 Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.
CVE-2024-32293 Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function.
CVE-2024-32292 Tenda W30E v1.0 V1.0.1.25(633) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
CVE-2024-32291 Tenda W30E v1.0 firmware v1.0.1.25(633) has a stack overflow vulnerability via the page parameter in the fromNatlimit function.
CVE-2024-32290 Tenda W30E v1.0 v1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromAddressNat function.
CVE-2024-32288 Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromwebExcptypemanFilter function.
CVE-2024-32287 Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the qos parameter in the fromqossetting function.
CVE-2024-32286 Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromVirtualSer function.
CVE-2024-32285 Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the password parameter in the formaddUserName function.
CVE-2024-32283 Tenda FH1203 V2.0.1.6 firmware has a command injection vulnerablility in formexeCommand function via the cmdinput parameter.
CVE-2024-32282 Tenda FH1202 v1.2.0.14(408) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
CVE-2024-32281 Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter.
CVE-2024-30891 A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution.
CVE-2024-30840 A Stack Overflow vulnerability in Tenda AC15 v15.03.05.18 allows attackers to cause a denial of service via the LISTEN parameter in the fromDhcpListClient function.
CVE-2024-30645 Tenda AC15V1.0 V15.03.20_multi has a command injection vulnerability via the deviceName parameter.
CVE-2024-30639 Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability in the page parameter of fromAddressNat function.
CVE-2024-30638 Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the entrys parameter in the fromAddressNat function.
CVE-2024-30637 Tenda F1202 v1.2.0.20(408) has a command injection vulnerablility in the formWriteFacMac function in the mac parameter.
CVE-2024-30636 Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the PPPOEPassword parameter in the formQuickIndex function.
CVE-2024-30635 Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability located in the funcpara1 parameter in the formSetCfm function.
CVE-2024-30634 Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the mitInterface parameter in the fromAddressNat function.
CVE-2024-30633 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the security parameter from the formWifiBasicSet function.
CVE-2024-30632 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the security_5g parameter from formWifiBasicSet function.
CVE-2024-30631 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the schedStartTime parameter from setSchedWifi function.
CVE-2024-30630 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the time parameter from saveParentControlInfo function.
CVE-2024-30629 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the list1 parameter from fromDhcpListClient function.
CVE-2024-30628 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the page parameter from fromAddressNat function.
CVE-2024-30627 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the deviceId parameter from saveParentControlInfo function.
CVE-2024-30626 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the schedEndTime parameter from setSchedWifi function.
CVE-2024-30625 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the entrys parameter from fromAddressNat function.
CVE-2024-30624 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the urls parameter from saveParentControlInfo function.
CVE-2024-30623 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the page parameter from fromDhcpListClient function.
CVE-2024-30622 Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the mitInterface parameter from fromAddressNat function.
CVE-2024-30621 Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan.
CVE-2024-30620 Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan.
CVE-2024-30613 Tenda AC15 v15.03.05.18 has a stack overflow vulnerability in the time parameter from the setSmartPowerManagement function.
CVE-2024-30612 Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function.
CVE-2024-30607 Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function.
CVE-2024-30606 Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the page parameter of the fromDhcpListClient function.
CVE-2024-30604 Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the list1 parameter of the fromDhcpListClient function.
CVE-2024-30603 Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the urls parameter of the saveParentControlInfo function.
CVE-2024-30602 Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function.
CVE-2024-30601 Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the time parameter of the saveParentControlInfo function.
CVE-2024-30600 Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function.
CVE-2024-30599 Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function.
CVE-2024-30598 Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability in the security_5g parameter of the formWifiBasicSet function.
CVE-2024-30597 Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability in the security parameter of the formWifiBasicSet function.
CVE-2024-30596 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the formSetDeviceName function.
CVE-2024-30595 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the addWifiMacFilter function.
CVE-2024-30594 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function.
CVE-2024-30593 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability located in the deviceName parameter of the formSetDeviceName function.
CVE-2024-30592 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the page parameter of the fromAddressNat function.
CVE-2024-30591 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the time parameter of the saveParentControlInfo function.
CVE-2024-30590 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function.
CVE-2024-30589 Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability in the entrys parameter of the fromAddressNat function.
CVE-2024-30588 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function.
CVE-2024-30587 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the urls parameter of the saveParentControlInfo function.
CVE-2024-30586 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the security_5g parameter of the formWifiBasicSet function.
CVE-2024-30585 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function.
CVE-2024-30584 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the security parameter of the formWifiBasicSet function.
CVE-2024-30583 Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the mitInterface parameter of the fromAddressNat function.
CVE-2024-3012 A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258298 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3011 A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3010 A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3009 A vulnerability has been found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258295. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3008 A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3007 A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-3006 A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2994 A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2993 A vulnerability was found in Tenda FH1203 2.0.1.6. It has been classified as critical. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258162 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2992 A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2991 A vulnerability has been found in Tenda FH1203 2.0.1.6 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2990 A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. This affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258159. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2989 A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258158 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2988 A vulnerability classified as critical was found in Tenda FH1203 2.0.1.6. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258157 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2987 A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2986 A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258155. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2985 A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258154 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2984 A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been classified as critical. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258153 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2983 A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258152. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2982 A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258151. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2981 A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2980 A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258149 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2979 A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2978 A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258147. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2977 A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2976 A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2903 A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2902 A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2901 A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2900 A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2899 A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2898 A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2897 A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2896 A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2895 A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2894 A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2893 A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2892 A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2891 A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2856 A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-28553 Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function.
CVE-2024-28551 Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the ssid parameter of form_fast_setting_wifi_set function.
CVE-2024-28550 Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the filePath parameter of formExpandDlnaFile function.
CVE-2024-2855 A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-28547 Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the firewallEn parameter of formSetFirewallCfg function.
CVE-2024-28545 Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload function.
CVE-2024-2854 A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-28537 Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function.
CVE-2024-28535 Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function.
CVE-2024-2853 A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2852 A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2851 A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2850 A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-28383 Tenda AX12 v1.0 v22.03.01.16 was discovered to contain a stack overflow via the ssid parameter in the sub_431CF0 function.
CVE-2024-2817 A vulnerability, which was classified as problematic, has been found in Tenda AC15 15.03.05.18. Affected by this issue is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257672. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2816 A vulnerability classified as problematic was found in Tenda AC15 15.03.05.18. Affected by this vulnerability is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2815 A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2814 A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2813 A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2812 A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2811 A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2810 A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2809 A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2808 A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2807 A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2806 A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2805 A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2764 A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2763 A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2711 A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2710 A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2709 A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2708 A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2707 A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2706 A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2705 A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2704 A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2703 A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2581 A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.
CVE-2024-25756 A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formWifiBasicSet function.
CVE-2024-25753 Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the formSetDeviceName function.
CVE-2024-25751 A Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetSysTime function.
CVE-2024-25748 A Stack Based Buffer Overflow vulnerability in tenda AC9 AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the fromSetIpMacBind function.
CVE-2024-25746 Stack Based Buffer Overflow vulnerability in Tenda AC9 v.3.0 with firmware version v.15.03.06.42_multi allows a remote attacker to execute arbitrary code via the add_white_node function.
CVE-2024-2560 A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2559 A vulnerability classified as problematic has been found in Tenda AC18 15.03.05.05. Affected is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257058 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2558 A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2547 A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2546 A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-25373 Tenda AC10V4.0 V16.03.10.20 was discovered to contain a stack overflow via the page parameter in the sub_49B384 function.
CVE-2024-2490 A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2489 A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2488 A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2487 A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2486 A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.
CVE-2024-2485 A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-24543 Buffer Overflow vulnerability in the function setSchedWifi in Tenda AC9 v.3.0, firmware version v.15.03.06.42_multi allows a remote attacker to cause a denial of service or run arbitrary code via crafted overflow data.
CVE-2024-24488 An issue in Shenzen Tenda Technology CP3V2.0 V11.10.00.2311090948 allows a local attacker to obtain sensitive information via the password component.
CVE-2024-0996 A vulnerability classified as critical has been found in Tenda i9 1.0.0.9(4122). This affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252261 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0995 A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been rated as critical. Affected by this issue is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252260. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0994 A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been declared as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252259. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0993 A vulnerability was found in Tenda i6 1.0.0.9(3857). It has been classified as critical. Affected is the function formWifiMacFilterGet of the file /goform/WifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-252258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0992 A vulnerability was found in Tenda i6 1.0.0.9(3857) and classified as critical. This issue affects the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252257 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0991 A vulnerability has been found in Tenda i6 1.0.0.9(3857) and classified as critical. This vulnerability affects the function formSetCfm of the file /goform/setcfm of the component httpd. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252256. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0990 A vulnerability, which was classified as critical, was found in Tenda i6 1.0.0.9(3857). This affects the function formSetAutoPing of the file /goform/setAutoPing of the component httpd. The manipulation of the argument ping1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0932 A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This issue affects the function setSmartPowerManagement. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0931 A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. This vulnerability affects the function saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0930 A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0929 A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been rated as critical. Affected by this issue is the function fromNatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-252134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0928 A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been declared as critical. Affected by this vulnerability is the function fromDhcpListClient. The manipulation of the argument page/listN leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0927 A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been classified as critical. Affected is the function fromAddressNat. The manipulation of the argument entrys/mitInterface/page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0926 A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This issue affects the function formWifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0925 A vulnerability has been found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This vulnerability affects the function formSetVirtualSer. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-252130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0924 A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function formSetPPTPServer. The manipulation of the argument startIp leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0923 A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this issue is the function formSetDeviceName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0922 A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this vulnerability is the function formQuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0542 A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. Affected by this issue is the function formWifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250712. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0541 A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. Affected by this vulnerability is the function formAddSysLogRule of the component httpd. The manipulation of the argument sysRulenEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250711. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0540 A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. Affected is the function formOfflineSet of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-250710 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0539 A vulnerability was found in Tenda W9 1.0.0.7(4456) and classified as critical. This issue affects the function formQosManage_user of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250709 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0538 A vulnerability has been found in Tenda W9 1.0.0.7(4456) and classified as critical. This vulnerability affects the function formQosManage_auto of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250708. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0537 A vulnerability, which was classified as critical, was found in Tenda W9 1.0.0.7(4456). This affects the function setWrlBasicInfo of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250707. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0536 A vulnerability, which was classified as critical, has been found in Tenda W9 1.0.0.7(4456). Affected by this issue is the function setWrlAccessList of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-250706 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0535 A vulnerability classified as critical was found in Tenda PA6 1.0.1.21. Affected by this vulnerability is the function cgiPortMapAdd of the file /portmap of the component httpd. The manipulation of the argument groupName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250705 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0534 A vulnerability classified as critical has been found in Tenda A15 15.13.07.13. Affected is an unknown function of the file /goform/SetOnlineDevName of the component Web-based Management Interface. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250704. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0533 A vulnerability was found in Tenda A15 15.13.07.13. It has been rated as critical. This issue affects some unknown processing of the file /goform/SetOnlineDevName of the component Web-based Management Interface. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250703. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0532 A vulnerability was found in Tenda A15 15.13.07.13. It has been declared as critical. This vulnerability affects unknown code of the file /goform/WifiExtraSet of the component Web-based Management Interface. The manipulation of the argument wpapsk_crypto2_4g leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-250702 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0531 A vulnerability was found in Tenda A15 15.13.07.13. It has been classified as critical. This affects an unknown part of the file /goform/setBlackRule of the component Web-based Management Interface. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250701 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-51972 Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp.
CVE-2023-51971 Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function getIptvInfo.
CVE-2023-51970 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formSetIptv.
CVE-2023-51969 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function getIptvInfo.
CVE-2023-51968 Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function getIptvInfo.
CVE-2023-51967 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function getIptvInfo.
CVE-2023-51966 Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function setIptvInfo.
CVE-2023-51965 Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function setIptvInfo.
CVE-2023-51964 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function setIptvInfo.
CVE-2023-51963 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function setIptvInfo.
CVE-2023-51962 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function setIptvInfo.
CVE-2023-51961 Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function formGetIptv.
CVE-2023-51960 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function formGetIptv.
CVE-2023-51959 Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function formGetIptv.
CVE-2023-51958 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function formGetIptv.
CVE-2023-51957 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formGetIptv.
CVE-2023-51956 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function formSetIptv
CVE-2023-51955 Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function formSetIptv.
CVE-2023-51954 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function formSetIptv.
CVE-2023-51953 Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formSetIptv.
CVE-2023-51952 Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function formSetIptv.
CVE-2023-51812 Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /goform/SetNetControlList.
CVE-2023-51102 Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formWifiMacFilterSet.
CVE-2023-51101 Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formSetUplinkInfo.
CVE-2023-51100 Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a command injection vulnerability via the function formGetDiagnoseInfo .
CVE-2023-51099 Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a command injection vulnerability via the function formexeCommand .
CVE-2023-51098 Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a command injection vulnerability via the function formSetDiagnoseInfo .
CVE-2023-51097 Tenda W9 V1.0.0.7(4456)_CN was discovered to contain a stack overflow via the function formSetAutoPing.
CVE-2023-51095 Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function formDelWlRfPolicy.
CVE-2023-51094 Tenda M3 V1.0.0.12(4856) was discovered to contain a Command Execution vulnerability via the function TendaTelnet.
CVE-2023-51093 Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function fromSetLocalVlanInfo.
CVE-2023-51092 Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function upgrade.
CVE-2023-51091 Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function R7WebsSecurityHandler.
CVE-2023-51090 Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow via the function formGetWeiXinConfig.
CVE-2023-50992 Tenda i29 v1.0 V1.0.0.5 was discovered to contain a stack overflow via the ip parameter in the setPing function.
CVE-2023-50991 Buffer Overflow vulnerability in Tenda i29 versions 1.0 V1.0.0.5 and 1.0 V1.0.0.2, allows remote attackers to cause a denial of service (DoS) via the pingIp parameter in the pingSet function.
CVE-2023-50990 Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the rebootTime parameter in the sysScheduleRebootSet function.
CVE-2023-50989 Tenda i29 v1.0 V1.0.0.5 was discovered to contain a command injection vulnerability via the pingSet function.
CVE-2023-50988 Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the bandwidth parameter in the wifiRadioSetIndoor function.
CVE-2023-50987 Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the time parameter in the sysTimeInfoSet function.
CVE-2023-50986 Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the time parameter in the sysLogin function.
CVE-2023-50985 Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the lanGw parameter in the lanCfgSet function.
CVE-2023-50984 Tenda i29 v1.0 V1.0.0.5 was discovered to contain a buffer overflow via the ip parameter in the spdtstConfigAndStart function.
CVE-2023-50983 Tenda i29 v1.0 V1.0.0.5 was discovered to contain a command injection vulnerability via the sysScheduleRebootSet function.
CVE-2023-50585 Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
CVE-2023-50002 Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formRebootMeshNode.
CVE-2023-50001 Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formUpgradeMeshOnline.
CVE-2023-50000 Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formResetMeshNode.
CVE-2023-49999 Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setUmountUSBPartition.
CVE-2023-49437 Tenda AX12 V22.03.01.46 has been discovered to contain a command injection vulnerability in the 'list' parameter at /goform/SetNetControlList.
CVE-2023-49436 Tenda AX9 V22.03.01.46 has been discovered to contain a command injection vulnerability in the 'list' parameter at /goform/SetNetControlList.
CVE-2023-49435 Tenda AX9 V22.03.01.46 is vulnerable to command injection.
CVE-2023-49434 Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'list' parameter at /goform/SetNetControlList.
CVE-2023-49433 Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'list' parameter at /goform/SetVirtualServerCfg.
CVE-2023-49432 Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'deviceList' parameter at /goform/setMacFilterCfg.
CVE-2023-49431 Tenda AX9 V22.03.01.46 has been discovered to contain a command injection vulnerability in the 'mac' parameter at /goform/SetOnlineDevName.
CVE-2023-49430 Tenda AX9 V22.03.01.46 has been found to contain a stack overflow vulnerability in the 'list' parameter at /goform/SetStaticRouteCfg.
CVE-2023-49429 Tenda AX9 V22.03.01.46 was discovered to contain a SQL command injection vulnerability in the 'setDeviceInfo' feature through the 'mac' parameter at /goform/setModules.
CVE-2023-49428 Tenda AX12 V22.03.01.46 has been discovered to contain a command injection vulnerability in the 'mac' parameter at /goform/SetOnlineDevName.
CVE-2023-49427 Buffer Overflow vulnerability in Tenda AX12 V22.03.01.46, allows remote attackers to cause a denial of service (DoS) via list parameter in SetNetControlList function.
CVE-2023-49426 Tenda AX12 V22.03.01.46 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg.
CVE-2023-49425 Tenda AX12 V22.03.01.46 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg .
CVE-2023-49424 Tenda AX12 V22.03.01.46 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.
CVE-2023-49411 Tenda W30E V16.01.0.12(4843) contains a stack overflow vulnerability via the function formDeleteMeshNode.
CVE-2023-49410 Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function via the function set_wan_status.
CVE-2023-49409 Tenda AX3 V16.03.12.11 was discovered to contain a Command Execution vulnerability via the function /goform/telnet.
CVE-2023-49408 Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the function set_device_name.
CVE-2023-49406 Tenda W30E V16.01.0.12(4843) was discovered to contain a Command Execution vulnerability via the function /goform/telnet.
CVE-2023-49405 Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function UploadCfg.
CVE-2023-49404 Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet.
CVE-2023-49403 Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setFixTools.
CVE-2023-49402 Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function localMsg.
CVE-2023-49047 Tenda AX1803 v1.0.0.1 contains a stack overflow via the devName parameter in the function formSetDeviceName.
CVE-2023-49046 Stack Overflow vulnerability in Tenda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the devName parameter in the function formAddMacfilterRule.
CVE-2023-49044 Stack Overflow vulnerability in Tenda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the ssid parameter in the function form_fast_setting_wifi_set.
CVE-2023-49043 Buffer Overflow vulnerability in Tenda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the wpapsk_crypto parameter in the function fromSetWirelessRepeat.
CVE-2023-49042 Heap Overflow vulnerability in Tenda AX1803 v.1.0.0.1 allows a remote attacker to execute arbitrary code via the schedStartTime parameter or the schedEndTime parameter in the function setSchedWifi.
CVE-2023-48964 Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/WifiMacFilterSet.
CVE-2023-48963 Tenda i6 V1.0.0.8(3856) is vulnerable to Buffer Overflow via /goform/wifiSSIDget.
CVE-2023-48111 Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the time parameter in the function saveParentControlInfo . This vulnerability allows attackers to cause a Denial of Service (DoS) attack
CVE-2023-48110 Tenda AX1803 v1.0.0.1 was discovered to contain a heap overflow via the urls parameter in the function saveParentControlInfo . This vulnerability allows attackers to cause a Denial of Service (DoS) attack
CVE-2023-48109 Tenda AX1803 v1.0.0.1 was discovered to contain a heap overflow via the deviceId parameter in the function saveParentControlInfo . This vulnerability allows attackers to cause a Denial of Service (DoS) attack
CVE-2023-47456 Tenda AX1806 V1.0.0.1 contains a stack overflow vulnerability in function sub_455D4, called by function fromSetWirelessRepeat.
CVE-2023-47455 Tenda AX1806 V1.0.0.1 contains a heap overflow vulnerability in setSchedWifi function, in which the src and v12 are directly obtained from http request parameter schedStartTime and schedEndTime without checking their size.
CVE-2023-4744 A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.
CVE-2023-47422 An access control issue in /usr/sbin/httpd in Tenda TX9 V1 V22.03.02.54, Tenda AX3 V3 V16.03.12.11, Tenda AX9 V1 V22.03.01.46, and Tenda AX12 V1 V22.03.01.46 allows attackers to bypass authentication on any endpoint via a crafted URL.
CVE-2023-46370 Tenda W18E V16.01.0.8(1576) has a command injection vulnerability via the hostName parameter in the formSetNetCheckTools function.
CVE-2023-46369 Tenda W18E V16.01.0.8(1576) contains a stack overflow vulnerability via the portMirrorMirroredPorts parameter in the formSetNetCheckTools function.
CVE-2023-46060 A Buffer Overflow vulnerability in Tenda AC500 v.2.0.1.9 allows a remote attacker to cause a denial of service via the port parameter at the goform/setVlanInfo component.
CVE-2023-45484 Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic.
CVE-2023-45483 Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time.
CVE-2023-45482 Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
CVE-2023-45481 Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.
CVE-2023-45480 Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878.
CVE-2023-45479 Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098.
CVE-2023-4498 Tenda N300 Wireless N VDSL2 Modem Router allows unauthenticated access to pages that in turn should be accessible to authenticated users only
CVE-2023-44023 Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2023-44022 Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2023-44021 Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the formSetClientState function.
CVE-2023-44020 Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
CVE-2023-44019 Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the mac parameter in the GetParentControlInfo function.
CVE-2023-44018 Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the domain parameter in the add_white_node function.
CVE-2023-44017 Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function.
CVE-2023-44016 Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2023-44015 Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the schedEndTime parameter in the setSchedWifi function.
CVE-2023-44014 Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain multiple stack overflows in the formSetMacFilterCfg function via the macFilterType and deviceList parameters.
CVE-2023-44013 Tenda AC10U v1.0 US_AC10UV1.0RTL_V15.03.06.49_multi_TDE01 was discovered to contain a stack overflow via the list parameter in the fromSetIpMacBind function.
CVE-2023-43886 A buffer overflow in the HTTP server component of Tenda RX9 Pro v22.03.02.20 might allow an authenticated attacker to overwrite memory.
CVE-2023-43885 Missing error handling in the HTTP server component of Tenda RX9 Pro Firmware V22.03.02.20 allows authenticated attackers to arbitrarily lock the device.
CVE-2023-42320 Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function.
CVE-2023-41563 Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo.
CVE-2023-41562 Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
CVE-2023-41561 Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.
CVE-2023-41560 Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter firewallEn at url /goform/SetFirewallCfg.
CVE-2023-41559 Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
CVE-2023-41558 Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg.
CVE-2023-41557 Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.
CVE-2023-41556 Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.
CVE-2023-41555 Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet.
CVE-2023-41554 Tenda AC9 V3.0 V15.03.06.42_multi was discovered to contain a stack overflow via parameter wpapsk_crypto at url /goform/WifiExtraSet.
CVE-2023-41553 Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg.
CVE-2023-41552 Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.
CVE-2023-40942 Tenda AC9 V3.0BR_V15.03.06.42_multi_TD01 was discovered stack overflow via parameter 'firewall_value' at url /goform/SetFirewallCfg.
CVE-2023-40915 Tenda AX3 v16.03.12.11 has a stack buffer overflow vulnerability detected at function form_fast_setting_wifi_set. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ssid parameter.
CVE-2023-40904 Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
CVE-2023-40902 Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
CVE-2023-40901 Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.
CVE-2023-40900 Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
CVE-2023-40899 Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
CVE-2023-40898 Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg.
CVE-2023-40897 Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo.
CVE-2023-40896 Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
CVE-2023-40895 Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
CVE-2023-40894 Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.
CVE-2023-40893 Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
CVE-2023-40892 Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi.
CVE-2023-40891 Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.
CVE-2023-40848 Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "sub_7D858."
CVE-2023-40847 Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "initIpAddrInfo." In the function, it reads in a user-provided parameter, and the variable is passed to the function without any length check.
CVE-2023-40846 Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function sub_90998.
CVE-2023-40845 Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'sub_34FD0.' In the function, it reads user provided parameters and passes variables to the function without any length checks.
CVE-2023-40844 Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function 'formWifiBasicSet.'
CVE-2023-40843 Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "sub_73004."
CVE-2023-40841 Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "add_white_node,"
CVE-2023-40840 Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "fromGetWirelessRepeat."
CVE-2023-40839 Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADF3C' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADF3C" function to execute commands.
CVE-2023-40838 Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability.
CVE-2023-40837 Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADD50' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADD50" function to execute commands.
CVE-2023-40830 Tenda AC6 v15.03.05.19 is vulnerable to Buffer Overflow as the Index parameter does not verify the length.
CVE-2023-40802 The get_parentControl_list_Info function does not verify the parameters entered by the user, causing a post-authentication heap overflow vulnerability in Tenda AC23 v16.03.07.45_cn
CVE-2023-40801 The sub_451784 function does not validate the parameters entered by the user, resulting in a stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn
CVE-2023-40800 The compare_parentcontrol_time function does not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn.
CVE-2023-40799 Tenda AC23 Vv16.03.07.45_cn is vulnerable to Buffer Overflow via sub_450A4C function.
CVE-2023-40798 In Tenda AC23 v16.03.07.45_cn, the formSetIPv6status and formGetWanParameter functions do not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability.
CVE-2023-40797 In Tenda AC23 v16.03.07.45_cn, the sub_4781A4 function does not validate the parameters entered by the user, resulting in a post-authentication stack overflow vulnerability.
CVE-2023-39829 Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function.
CVE-2023-39828 Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
CVE-2023-39827 Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function.
CVE-2023-39786 Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sscanf function.
CVE-2023-39785 Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the set_qosMib_list function.
CVE-2023-39784 Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the save_virtualser_data function.
CVE-2023-39673 Tenda AC15 V1.0BR_V15.03.05.18_multi_TD01 was discovered to contain a buffer overflow via the function FUN_00010e34().
CVE-2023-39672 Tenda WH450 v1.0.0.18 was discovered to contain a buffer overflow via the function fgets.
CVE-2023-39670 Tenda AC6 _US_AC6V1.0BR_V15.03.05.16 was discovered to contain a buffer overflow via the function fgets.
CVE-2023-38940 Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2023-38939 Tenda F1202 V1.2.0.9 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the mit_ssid parameter in the formWrlsafeset function.
CVE-2023-38938 Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter at /L7Im.
CVE-2023-38937 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
CVE-2023-38936 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2023-38935 Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
CVE-2023-38934 Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
CVE-2023-38933 Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
CVE-2023-38932 Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter in the SafeEmailFilter function.
CVE-2023-38931 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
CVE-2023-38930 Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2023-38929 Tenda 4G300 v1.01.42 was discovered to contain a stack overflow via the page parameter at /VirtualSer.
CVE-2023-38823 Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
CVE-2023-37723 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting.
CVE-2023-37722 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeUrlFilter.
CVE-2023-37721 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter.
CVE-2023-37719 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter.
CVE-2023-37718 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter.
CVE-2023-37717 Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
CVE-2023-37716 Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
CVE-2023-37715 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm.
CVE-2023-37714 Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
CVE-2023-37712 Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function.
CVE-2023-37711 Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.
CVE-2023-37710 Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
CVE-2023-37707 Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function.
CVE-2023-37706 Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function.
CVE-2023-37705 Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function.
CVE-2023-37704 Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
CVE-2023-37703 Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2023-37702 Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
CVE-2023-37701 Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2023-37700 Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2023-37144 Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.
CVE-2023-34571 Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet.
CVE-2023-34570 Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName.
CVE-2023-34569 Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList.
CVE-2023-34568 Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
CVE-2023-34567 Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
CVE-2023-34566 Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo.
CVE-2023-33675 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function.
CVE-2023-33673 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
CVE-2023-33672 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function.
CVE-2023-33671 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function.
CVE-2023-33670 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function.
CVE-2023-33669 Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function.
CVE-2023-33530 There is a command injection vulnerability in the Tenda G103 Gigabit GPON Terminal with firmware version V1.0.0.5. If an attacker gains web management privileges, they can inject commands gaining shell privileges.
CVE-2023-31587 Tenda AC5 router V15.03.06.28 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac.
CVE-2023-30378 In Tenda AC15 V15.03.05.19, the function "sub_8EE8" contains a stack-based buffer overflow vulnerability.
CVE-2023-30376 In Tenda AC15 V15.03.05.19, the function "henan_pppoe_user" contains a stack-based buffer overflow vulnerability.
CVE-2023-30375 In Tenda AC15 V15.03.05.19, the function "getIfIp" contains a stack-based buffer overflow vulnerability.
CVE-2023-30373 In Tenda AC15 V15.03.05.19, the function "xian_pppoe_user" contains a stack-based buffer overflow vulnerability.
CVE-2023-30372 In Tenda AC15 V15.03.05.19, The function "xkjs_ver32" contains a stack-based buffer overflow vulnerability.
CVE-2023-30371 In Tenda AC15 V15.03.05.19, the function "sub_ED14" contains a stack-based buffer overflow vulnerability.
CVE-2023-30370 In Tenda AC15 V15.03.05.19, the function GetValue contains a stack-based buffer overflow vulnerability.
CVE-2023-30369 Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow.
CVE-2023-30368 Tenda AC5 V15.03.06.28 is vulnerable to Buffer Overflow via the initWebs function.
CVE-2023-30356 Missing Support for an Integrity Check in Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 allows attackers to update the device with crafted firmware
CVE-2023-30354 Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against physical access to U-Boot via the UART: the Wi-Fi password is shown, and the hardcoded boot password can be inserted for console access.
CVE-2023-30353 Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 allows unauthenticated remote code execution via an XML document.
CVE-2023-30352 Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for the RTSP feed.
CVE-2023-30351 Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for root which is stored using weak encryption. This vulnerability allows attackers to connect to the TELNET service (or UART) by using the exposed credentials.
CVE-2023-30135 Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName parameter in the setUsbUnload function.
CVE-2023-29681 Cleartext Transmission in cookie:ecos_pw: in Tenda N301 v6.0, firmware v12.03.01.06_pt allows an authenticated attacker on the LAN or WLAN to intercept communications with the router and obtain the password.
CVE-2023-29680 Cleartext Transmission in set-cookie:ecos_pw: Tenda N301 v6.0, Firmware v12.02.01.61_multi allows an authenticated attacker on the LAN or WLAN to intercept communications with the router and obtain the password.
CVE-2023-2923 A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Affected by this vulnerability is the function fromDhcpListClient. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-230077 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-27240 Tenda AX3 V16.03.12.11 was discovered to contain a command injection vulnerability via the lanip parameter at /goform/AdvSetLanip.
CVE-2023-27239 Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the shareSpeed parameter at /goform/WifiGuestSet.
CVE-2023-27079 Command Injection vulnerability found in Tenda G103 v.1.0.05 allows an attacker to obtain sensitive information via a crafted package
CVE-2023-27076 Command injection vulnerability found in Tenda G103 v.1.0.0.5 allows attacker to execute arbitrary code via a the language parameter.
CVE-2023-27065 Tenda V15V1.0 V15.11.0.14(1521_3190_1058) was discovered to contain a buffer overflow vulnerability via the picName parameter in the formDelWewifiPi function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2023-27064 Tenda V15V1.0 V15.11.0.14(1521_3190_1058) was discovered to contain a buffer overflow vulnerability via the index parameter in the formDelDnsForward function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2023-27063 Tenda V15V1.0 V15.11.0.14(1521_3190_1058) was discovered to contain a buffer overflow vulnerability via the DNSDomainName parameter in the formModifyDnsForward function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2023-27062 Tenda V15V1.0 was discovered to contain a buffer overflow vulnerability via the gotoUrl parameter in the formPortalAuth function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2023-27061 Tenda V15V1.0 V15.11.0.14(1521_3190_1058) was discovered to contain a buffer overflow vulnerability via the wifiFilterListRemark parameter in the modifyWifiFilterRules function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2023-27042 Tenda AX3 V16.03.12.11 is vulnerable to Buffer Overflow via /goform/SetFirewallCfg.
CVE-2023-27021 Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27020 Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27019 Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27018 Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27017 Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45DC58 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27016 Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27015 Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_4A75C0 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27014 Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_46AC38 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27013 Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-27012 Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-26976 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2023-26806 Tenda W20E v15.11.0.6(US_W20EV4.0br_v15.11.0.6(1068_1546_841 is vulnerable to Buffer Overflow via function formSetSysTime,
CVE-2023-26805 Tenda W20E v15.11.0.6 (US_W20EV4.0br_v15.11.0.6(1068_1546_841)_CN_TDC) is vulnerable to Buffer Overflow via function formIPMacBindModify.
CVE-2023-2649 A vulnerability was found in Tenda AC23 16.03.07.45_cn. It has been declared as critical. This vulnerability affects unknown code of the file /bin/ate of the component Service Port 7329. The manipulation of the argument v2 leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-228778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-25235 Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid.
CVE-2023-25234 Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface.
CVE-2023-25233 Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInterface.
CVE-2023-25231 Tenda Router W30E V1.0.1.25(633) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInterface.
CVE-2023-25220 Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the add_white_node function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-25219 Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromDhcpListClient function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-25218 Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-25217 Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formWifiBasicSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-25216 Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-25215 Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-25214 Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-25213 Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the check_param_changed function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-25212 Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetWirelessRepeat function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-25211 Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-25210 Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetSysTime function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
CVE-2023-24334 A stack overflow vulnerability in Tenda AC23 with firmware version US_AC23V1.0re_V16.03.07.45_cn_TDC01 allows attackers to run arbitrary commands via schedStartTime parameter.
CVE-2023-24333 A stack overflow vulnerability in Tenda AC21 with firmware version US_AC21V1.0re_V16.03.08.15_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/openSchedWifi.
CVE-2023-24332 A stack overflow vulnerability in Tenda AC6 with firmware version US_AC6V5.0re_V03.03.02.01_cn_TDC01 allows attackers to run arbitrary commands via crafted POST request to /goform/PowerSaveSet.
CVE-2023-24212 Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the timeType function at /goform/SetSysTimeCfg.
CVE-2023-24170 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/fromSetWirelessRepeat.
CVE-2023-24169 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_0007343c.
CVE-2023-24167 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/add_white_node.
CVE-2023-24166 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet.
CVE-2023-24165 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/initIpAddrInfo.
CVE-2023-24164 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/FUN_000c2318.
CVE-2023-23080 Certain Tenda products are vulnerable to command injection. This affects Tenda CP7 Tenda CP7<=V11.10.00.2211041403 and Tenda CP3 v.10 Tenda CP3 v.10<=V20220906024_2025 and Tenda IT7-PCS Tenda IT7-PCS<=V2209020914 and Tenda IT7-LCS Tenda IT7-LCS<=V2209020914 and Tenda IT7-PRS Tenda IT7-PRS<=V2209020908.
CVE-2023-0782 A vulnerability was found in Tenda AC23 16.03.07.45 and classified as critical. Affected by this issue is the function formSetSysToolDDNS/formGetSysToolDDNS of the file /bin/httpd. The manipulation leads to out-of-bounds write. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220640.
CVE-2022-48130 Tenda W20E v15.11.0.6 was discovered to contain multiple stack overflows in the function formSetStaticRoute via the parameters staticRouteNet, staticRouteMask, staticRouteGateway, staticRouteWAN.
CVE-2022-47128 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey2 parameter at /goform/WifiBasicSet.
CVE-2022-47127 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlPwd parameter at /goform/WifiBasicSet.
CVE-2022-47126 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn parameter at /goform/WifiBasicSet.
CVE-2022-47125 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlEn_5g parameter at /goform/WifiBasicSet.
CVE-2022-47124 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey4 parameter at /goform/WifiBasicSet.
CVE-2022-47123 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey3 parameter at /goform/WifiBasicSet.
CVE-2022-47122 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wrlPwd_5g parameter at /goform/WifiBasicSet.
CVE-2022-47121 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey parameter at /goform/WifiBasicSet.
CVE-2022-47120 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet.
CVE-2022-47119 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the ssid parameter at /goform/WifiBasicSet.
CVE-2022-47118 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepkey1 parameter at /goform/WifiBasicSet.
CVE-2022-47117 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the security parameter at /goform/WifiBasicSet.
CVE-2022-47116 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the SYSPS parameter at /goform/SysToolChangePwd.
CVE-2022-47115 Tenda A15 V15.13.07.13 was discovered to contain a stack overflow via the wepauth parameter at /goform/WifiBasicSet.
CVE-2022-46551 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the time parameter at /goform/saveParentControlInfo.
CVE-2022-46550 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the urls parameter at /goform/saveParentControlInfo.
CVE-2022-46549 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/saveParentControlInfo.
CVE-2022-46548 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/DhcpListClient.
CVE-2022-46547 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/VirtualSer.
CVE-2022-46546 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the entrys parameter at /goform/RouteStatic.
CVE-2022-46545 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/NatStaticSetting.
CVE-2022-46544 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the cmdinput parameter at /goform/exeCommand.
CVE-2022-46543 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the mitInterface parameter at /goform/addressNat.
CVE-2022-46542 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/addressNat.
CVE-2022-46541 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the ssid parameter at /goform/fast_setting_wifi_set.
CVE-2022-46540 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the entrys parameter at /goform/addressNat.
CVE-2022-46539 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the security_5g parameter at /goform/WifiBasicSet.
CVE-2022-46538 Tenda F1203 V2.0.1.6 was discovered to contain a command injection vulnerability via the mac parameter at /goform/WriteFacMac.
CVE-2022-46537 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the security parameter at /goform/WifiBasicSet.
CVE-2022-46536 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the limitSpeedUp parameter at /goform/SetClientState.
CVE-2022-46535 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/SetClientState.
CVE-2022-46534 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the speed_dir parameter at /goform/SetSpeedWan.
CVE-2022-46533 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the limitSpeed parameter at /goform/SetClientState.
CVE-2022-46532 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceMac parameter at /goform/addWifiMacFilter.
CVE-2022-46531 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/addWifiMacFilter.
CVE-2022-46530 Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the mac parameter at /goform/GetParentControlInfo.
CVE-2022-46109 Tenda AC15 V15.03.06.23 is vulnerable to Buffer Overflow via function formSetClientState.
CVE-2022-45997 Tenda W20E V16.01.0.6(3392) is vulnerable to Buffer Overflow.
CVE-2022-45996 Tenda W20E V16.01.0.6(3392) is vulnerable to Command injection via cmd_get_ping_output.
CVE-2022-45995 There is an unauthorized buffer overflow vulnerability in Tenda AX12 v22.03.01.21 _ cn. This vulnerability can cause the web service not to restart or even execute arbitrary code. It is a different vulnerability from CVE-2022-2414.
CVE-2022-45980 Tenda AX12 V22.03.01.21_CN was discovered to contain a Cross-Site Request Forgery (CSRF) via /goform/SysToolRestoreSet .
CVE-2022-45979 Tenda AX12 v22.03.01.21_CN was discovered to contain a stack overflow via the ssid parameter at /goform/fast_setting_wifi_set .
CVE-2022-45977 Tenda AX12 V22.03.01.21_CN was found to have a command injection vulnerability via /goform/setMacFilterCfg function.
CVE-2022-45781 Buffer Overflow vulnerability in Tenda AX1803 v1.0.0.1_2994 and earlier allows attackers to run arbitrary code via /goform/SetOnlineDevName.
CVE-2022-45674 Tenda AC6V1.0 V15.03.05.19 is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolReboot.
CVE-2022-45673 Tenda AC6V1.0 V15.03.05.19 is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolRestoreSet.
CVE-2022-45672 Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the formWx3AuthorizeSet function.
CVE-2022-45671 Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the appData parameter in the formSetAppFilterRule function.
CVE-2022-45670 Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the ping1 parameter in the formSetAutoPing function.
CVE-2022-45669 Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the index parameter in the formWifiMacFilterGet function.
CVE-2022-45668 Tenda i22 V1.0.0.3(4687) is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolReboot.
CVE-2022-45667 Tenda i22 V1.0.0.3(4687) is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolRestoreSet.
CVE-2022-45666 Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the list parameter in the formwrlSSIDset function.
CVE-2022-45665 Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the funcpara1 parameter in the formSetCfm function.
CVE-2022-45664 Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the list parameter in the formwrlSSIDget function.
CVE-2022-45663 Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the index parameter in the formWifiMacFilterSet function.
CVE-2022-45661 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the setSmartPowerManagement function.
CVE-2022-45660 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedStartTime parameter in the setSchedWifi function.
CVE-2022-45659 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
CVE-2022-45658 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the schedEndTime parameter in the setSchedWifi function.
CVE-2022-45657 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function.
CVE-2022-45656 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the time parameter in the fromSetSysTime function.
CVE-2022-45655 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the timeZone parameter in the form_fast_setting_wifi_set function.
CVE-2022-45654 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2022-45653 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the page parameter in the fromNatStaticSetting function.
CVE-2022-45652 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the startIp parameter in the formSetPPTPServer function.
CVE-2022-45651 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the list parameter in the formSetVirtualSer function.
CVE-2022-45650 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the firewallEn parameter in the formSetFirewallCfg function.
CVE-2022-45649 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the endIp parameter in the formSetPPTPServer function.
CVE-2022-45648 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the devName parameter in the formSetDeviceName function.
CVE-2022-45647 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeed parameter in the formSetClientState function.
CVE-2022-45646 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the limitSpeedUp parameter in the formSetClientState function.
CVE-2022-45645 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceMac parameter in the addWifiMacFilter function.
CVE-2022-45644 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the formSetClientState function.
CVE-2022-45643 Tenda AC6V1.0 V15.03.05.19 was discovered to contain a buffer overflow via the deviceId parameter in the addWifiMacFilter function.
CVE-2022-45641 Tenda AC6V1.0 V15.03.05.19 is vulnerable to Buffer Overflow via formSetMacFilterCfg.
CVE-2022-45640 Tenda Tenda AC6V1.0 V15.03.05.19 is affected by buffer overflow. Causes a denial of service (local).
CVE-2022-45525 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the downaction parameter at /goform/CertListInfo.
CVE-2022-45524 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the opttype parameter at /goform/IPSECsave.
CVE-2022-45523 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/L7Im.
CVE-2022-45522 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeClientFilter.
CVE-2022-45521 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeUrlFilter.
CVE-2022-45520 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/qossetting.
CVE-2022-45519 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the Go parameter at /goform/SafeMacFilter.
CVE-2022-45518 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SetIpBind.
CVE-2022-45517 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/VirtualSer.
CVE-2022-45516 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/NatStaticSetting.
CVE-2022-45515 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the entries parameter at /goform/addressNat.
CVE-2022-45514 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/webExcptypemanFilter.
CVE-2022-45513 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/P2pListFilter.
CVE-2022-45512 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeEmailFilter.
CVE-2022-45511 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the PPPOEPassword parameter at /goform/QuickIndex.
CVE-2022-45510 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the mit_ssid_index parameter at /goform/AdvSetWrlsafeset.
CVE-2022-45509 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the account parameter at /goform/addUserName.
CVE-2022-45508 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the new_account parameter at /goform/editUserName.
CVE-2022-45507 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the editNameMit parameter at /goform/editFileName.
CVE-2022-45506 Tenda W30E v1.0.1.25(633) was discovered to contain a command injection vulnerability via the fileNameMit parameter at /goform/delFileName.
CVE-2022-45505 Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the cmdinput parameter at /goform/exeCommand.
CVE-2022-45504 An issue in the component tpi_systool_handle(0) (/goform/SysToolRestoreSet) of Tenda W6-S v1.0.0.4(510) allows unauthenticated attackers to arbitrarily reboot the device.
CVE-2022-45503 Tenda W6-S v1.0.0.4(510) was discovered to contain a stack overflow via the linkEn parameter at /goform/setAutoPing.
CVE-2022-45501 Tenda W6-S v1.0.0.4(510) was discovered to contain a stack overflow via the wl_radio parameter at /goform/wifiSSIDset.
CVE-2022-45499 Tenda W6-S v1.0.0.4(510) was discovered to contain a stack overflow via the wl_radio parameter at /goform/WifiMacFilterGet.
CVE-2022-45498 An issue in the component tpi_systool_handle(0) (/goform/SysToolReboot) of Tenda W6-S v1.0.0.4(510) allows unauthenticated attackers to arbitrarily reboot the device.
CVE-2022-45497 Tenda W6-S v1.0.0.4(510) was discovered to contain a command injection vulnerability in the tpi_get_ping_output function at /goform/exeCommand.
CVE-2022-45337 Tenda TX9 Pro v22.03.02.10 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind.
CVE-2022-45043 Tenda AX12 V22.03.01.16_cn is vulnerable to command injection via goform/fast_setting_internet_set.
CVE-2022-44932 An access control issue in Tenda A18 v15.13.07.09 allows unauthenticated attackers to access the Telnet service.
CVE-2022-44931 Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet.
CVE-2022-44367 Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setUplinkInfo.
CVE-2022-44366 Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setDiagnoseInfo.
CVE-2022-44365 Tenda i21 V1.0.0.14(4656) has a stack overflow vulnerability via /goform/setSysPwd.
CVE-2022-44363 Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setSnmpInfo.
CVE-2022-44362 Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/AddSysLogRule.
CVE-2022-44183 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetWifiGuestBasic.
CVE-2022-44180 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function addWifiMacFilter.
CVE-2022-44178 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow. via function formWifiWpsOOB.
CVE-2022-44177 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formWifiWpsStart.
CVE-2022-44176 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function fromSetRouteStatic.
CVE-2022-44175 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetMacFilterCfg.
CVE-2022-44174 Tenda AC18 V15.03.05.05 is vulnerable to Buffer Overflow via function formSetDeviceName.
CVE-2022-44172 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function R7WebsSecurityHandler.
CVE-2022-44171 Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via function form_fast_setting_wifi_set.
CVE-2022-44169 Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function formSetVirtualSer.
CVE-2022-44168 Tenda AC15 V15.03.05.18 is vulnerable to Buffer Overflow via function fromSetRouteStatic..
CVE-2022-44167 Tenda AC15 V15.03.05.18 is avulnerable to Buffer Overflow via function formSetPPTPServer.
CVE-2022-44163 Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function formSetMacFilterCfg.
CVE-2022-44158 Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function via set_device_name.
CVE-2022-44156 Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow via function formSetIpMacBind.
CVE-2022-43260 Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime function.
CVE-2022-43259 Tenda AC15 V15.03.05.18 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function.
CVE-2022-43108 Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
CVE-2022-43107 Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the time parameter in the setSmartPowerManagement function.
CVE-2022-43106 Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the schedStartTime parameter in the setSchedWifi function.
CVE-2022-43105 Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function.
CVE-2022-43104 Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
CVE-2022-43103 Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the list parameter in the formSetQosBand function.
CVE-2022-43102 Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function.
CVE-2022-43101 Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
CVE-2022-43029 Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the time parameter at /goform/SetSysTimeCfg.
CVE-2022-43028 Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the timeZone parameter at /goform/SetSysTimeCfg.
CVE-2022-43027 Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the firewallEn parameter at /goform/SetFirewallCfg.
CVE-2022-43026 Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the endIp parameter at /goform/SetPptpServerCfg.
CVE-2022-43025 Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the startIp parameter at /goform/SetPptpServerCfg.
CVE-2022-43024 Tenda TX3 US_TX3V1.0br_V16.03.13.11_multi_TDE01 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.
CVE-2022-42233 Tenda 11N with firmware version V5.07.33_cn suffers from an Authentication Bypass vulnerability.
CVE-2022-42171 Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/saveParentControlInfo.
CVE-2022-42170 Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formWifiWpsStart.
CVE-2022-42169 Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/addWifiMacFilter.
CVE-2022-42168 Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromSetIpMacBind.
CVE-2022-42167 Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetFirewallCfg.
CVE-2022-42166 Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetSpeedWan.
CVE-2022-42165 Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetDeviceName.
CVE-2022-42164 Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/formSetClientState.
CVE-2022-42163 Tenda AC10 V15.03.06.23 contains a Stack overflow vulnerability via /goform/fromNatStaticSetting.
CVE-2022-42087 Tenda AX1803 US_AX1803v2.0br_v1.0.0.1_2994_CN_ZGYD01_4 is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolReboot.
CVE-2022-42086 Tenda AX1803 US_AX1803v2.0br_v1.0.0.1_2994_CN_ZGYD01_4 is vulnerable to Cross Site Request Forgery (CSRF) via function TendaAteMode.
CVE-2022-42081 Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a stack overflow via sched_end_time parameter.
CVE-2022-42080 Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a heap overflow via sched_start_time parameter.
CVE-2022-42079 Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 was discovered to contain a stack overflow via the function formWifiBasicSet.
CVE-2022-42078 Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolRestoreSet.
CVE-2022-42077 Tenda AC1206 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01 is vulnerable to Cross Site Request Forgery (CSRF) via function fromSysToolReboot.
CVE-2022-42060 Tenda AC1200 Router Model W15Ev2 V15.11.0.10(1576) was discovered to contain a stack overflow via the setWanPpoe function. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
CVE-2022-42058 Tenda AC1200 Router Model W15Ev2 V15.11.0.10(1576) was discovered to contain a stack overflow via the setRemoteWebManage function. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
CVE-2022-42053 Tenda AC1200 Router Model W15Ev2 V15.11.0.10(1576) was discovered to contain a command injection vulnerability via the PortMappingServer parameter in the setPortMapping function.
CVE-2022-41485 Tenda AC1200 US_AC6V2.0RTL_V15.03.06.51_multi_TDE01 was discovered to contain a buffer overflow in the 0x47ce00 function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2022-41484 Tenda AC1900 AP500(US)_V1_180320(Beta) was discovered to contain a buffer overflow in the 0x32384 function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2022-41483 Tenda AC1200 US_AC6V2.0RTL_V15.03.06.51_multi_TDE01 was discovered to contain a buffer overflow in the 0x4a12cc function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2022-41482 Tenda AC1200 US_AC6V2.0RTL_V15.03.06.51_multi_TDE01 was discovered to contain a buffer overflow in the 0x47c5dc function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2022-41481 Tenda AC1200 US_AC6V2.0RTL_V15.03.06.51_multi_TDE01 was discovered to contain a buffer overflow in the 0x47de1c function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2022-41480 Tenda AC1200 US_AC6V2.0RTL_V15.03.06.51_multi_TDE01 was discovered to contain a buffer overflow in the 0x475dc function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CVE-2022-41396 Tenda AC1200 Router Model W15Ev2 V15.11.0.10(1576) was discovered to contain multiple command injection vulnerabilities in the function setIPsecTunnelList via the IPsecLocalNet and IPsecRemoteNet parameters.
CVE-2022-41395 Tenda AC1200 Router Model W15Ev2 V15.11.0.10(1576) was discovered to contain a command injection vulnerability via the dmzHost parameter in the setDMZ function.
CVE-2022-40942 Tenda TX3 US_TX3V1.0br_V16.03.13.11 is vulnerable to stack overflow via compare_parentcontrol_time.
CVE-2022-40876 In Tenda ax1803 v1.0.0.1, the http requests handled by the fromAdvSetMacMtuWan functions, wanSpeed, cloneType, mac, can cause a stack overflow and enable remote code execution (RCE).
CVE-2022-40875 Tenda AX1803 v1.0.0.1 was discovered to contain a heap overflow in the function GetParentControlInfo.
CVE-2022-40874 Tenda AX1803 v1.0.0.1 was discovered to contain a heap overflow vulnerability in the GetParentControlInfo function, which can cause a denial of service attack through a carefully constructed http request.
CVE-2022-40869 Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function fromDhcpListClient with a combined parameter "list*" ("%s%d","list").
CVE-2022-40868 Tenda W20E router V15.11.0.6 (US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC) contains a stack overflow vulnerability in the function formDelDhcpRule with the request /goform/delDhcpRules/
CVE-2022-40867 Tenda W20E router V15.11.0.6 (US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC) contains a stack overflow vulnerability in the function formIPMacBindDel with the request /goform/delIpMacBind/
CVE-2022-40866 Tenda W20E router V15.11.0.6 (US_W20EV4.0br_V15.11.0.6(1068_1546_841)_CN_TDC) contains a stack overflow vulnerability in the function formSetDebugCfg with request /goform/setDebugCfg/
CVE-2022-40865 Tenda AC15 and AC18 routers V15.03.05.19 contain heap overflow vulnerabilities in the function setSchedWifi with the request /goform/openSchedWifi/
CVE-2022-40864 Tenda AC15 and AC18 routers V15.03.05.19 contain stack overflow vulnerabilities in the function setSmartPowerManagement with the request /goform/PowerSaveSet
CVE-2022-40862 Tenda AC15 and AC18 router V15.03.05.19 contains stack overflow vulnerability in the function fromNatStaticSetting with the request /goform/NatStaticSetting
CVE-2022-40861 Tenda AC18 router V15.03.05.19 contains a stack overflow vulnerability in the formSetQosBand->FUN_0007db78 function with the request /goform/SetNetControlList/
CVE-2022-40860 Tenda AC15 router V15.03.05.19 contains a stack overflow vulnerability in the function formSetQosBand->FUN_0007dd20 with request /goform/SetNetControlList
CVE-2022-40855 Tenda W20E router V15.11.0.6 contains a stack overflow in the function formSetPortMapping with post request 'goform/setPortMapping/'. This vulnerability allows attackers to cause a Denial of Service (DoS) or Remote Code Execution (RCE) via the portMappingServer, portMappingProtocol, portMappingWan, porMappingtInternal, and portMappingExternal parameters.
CVE-2022-40854 Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set
CVE-2022-40853 Tenda AC15 router V15.03.05.19 contains a stack overflow via the list parameter at /goform/fast_setting_wifi_set
CVE-2022-40851 Tenda AC15 V15.03.05.19 contained a stack overflow via the function fromAddressNat.
CVE-2022-40847 In Tenda AC1200 Router model W15Ev2 V15.11.0.10(1576), there exists a command injection vulnerability in the function formSetFixTools. This vulnerability allows attackers to run arbitrary commands on the server via the hostname parameter.
CVE-2022-40846 In Tenda AC1200 Router model W15Ev2 V15.11.0.10(1576), a Stored Cross Site Scripting (XSS) vulnerability exists allowing an attacker to execute JavaScript code via the applications stored hostname.
CVE-2022-40845 The Tenda AC1200 Router model W15Ev2 V15.11.0.10(1576) is affected by a password exposure vulnerability. When combined with the improper authorization/improper session management vulnerability, an attacker with access to the router may be able to expose sensitive information which they're not explicitly authorized to have.
CVE-2022-40844 In Tenda (Shenzhen Tenda Technology Co., Ltd) AC1200 Router model W15Ev2 V15.11.0.10(1576), a Stored Cross Site Scripting (XSS) issue exists allowing an attacker to execute JavaScript code via the applications website filtering tab, specifically the URL body.
CVE-2022-40843 The Tenda AC1200 V-W15Ev2 V15.11.0.10(1576) router is vulnerable to improper authorization / improper session management that allows the router login page to be bypassed. This leads to authenticated attackers having the ability to read the routers syslog.log file which contains the MD5 password of the Administrator's user account.
CVE-2022-40107 Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formexeCommand function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string.
CVE-2022-40106 Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the set_local_time function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string.
CVE-2022-40105 Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formWifiMacFilterGet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string.
CVE-2022-40104 Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formwrlSSIDget function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string.
CVE-2022-40103 Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formSetAutoPing function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string.
CVE-2022-40102 Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formwrlSSIDset function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string.
CVE-2022-40101 Tenda i9 v1.0.0.8(3828) was discovered to contain a buffer overflow via the formWifiMacFilterSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string.
CVE-2022-40100 Tenda i9 v1.0.0.8(3828) was discovered to contain a command injection vulnerability via the FormexeCommand function.
CVE-2022-40076 Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: fromSetWifiGusetBasic.
CVE-2022-40075 Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, form_fast_setting_wifi_set.
CVE-2022-40074 Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, setSchedWifi.
CVE-2022-40073 Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, saveParentControlInfo.
CVE-2022-40072 Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: setSmartPowerManagement.
CVE-2022-40071 Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, formSetDeviceName.
CVE-2022-40070 Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via bin/httpd, function: formSetFirewallCfg.
CVE-2022-40069 ]Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: fromSetSysTime.
CVE-2022-40068 Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: formSetQosBand.
CVE-2022-40067 Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: formSetVirtualSer.
CVE-2022-40010 Tenda AC6 AC1200 Smart Dual-Band WiFi Router 15.03.06.50_multi was discovered to contain a cross-site scripting (XSS) vulnerability via the deviceId parameter in the Parental Control module.
CVE-2022-38831 Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/SetNetControlList
CVE-2022-38830 Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setIPv6Status.
CVE-2022-38829 Tenda RX9_Pro V22.03.02.10 is vulnerable to Buffer Overflow via httpd/setMacFilterCfg.
CVE-2022-38571 Tenda M3 V1.0.0.12(4856) was discovered to contain a buffer overflow in the function formSetGuideListItem.
CVE-2022-38570 Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow in the function formDelPushedAd. This vulnerability allows attackers to cause a Denial of Service (DoS) via the adPushUID parameter.
CVE-2022-38569 Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow in the function formDelAd.
CVE-2022-38568 Tenda M3 V1.0.0.12(4856) was discovered to contain a heap buffer overflow vulnerability in the function formSetFixTools. This vulnerability allows attackers to cause a Denial of Service (DoS) via the hostname parameter.
CVE-2022-38567 Tenda M3 V1.0.0.12(4856) was discovered to contain a stack overflow vulnerability in the function formSetAdConfigInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via the authIPs parameter.
CVE-2022-38566 Tenda M3 V1.0.0.12(4856) was discovered to contain a heap buffer overflow vulnerability in the function formEmailTest. This vulnerability allows attackers to cause a Denial of Service (DoS) via the mailname parameter.
CVE-2022-38565 Tenda M3 V1.0.0.12(4856) was discovered to contain a heap buffer overflow vulnerability in the function formEmailTest. This vulnerability allows attackers to cause a Denial of Service (DoS) via the mailpwd parameter.
CVE-2022-38564 Tenda M3 V1.0.0.12(4856) was discovered to contain a buffer overflow vulnerability in the function formSetPicListItem. This vulnerability allows attackers to cause a Denial of Service (DoS) via the adItemUID parameter.
CVE-2022-38563 Tenda M3 V1.0.0.12(4856) was discovered to contain a heap buffer overflow vulnerability in the function formSetFixTools. This vulnerability allows attackers to cause a Denial of Service (DoS) via the MACAddr parameter.
CVE-2022-38562 Tenda M3 V1.0.0.12(4856) was discovered to contain a heap buffer overflow vulnerability in the function formSetFixTools. This vulnerability allows attackers to cause a Denial of Service (DoS) via the lan parameter.
CVE-2022-38510 Tenda_TX9pro V22.03.02.10 was discovered to contain a buffer overflow via the component httpd/SetNetControlList.
CVE-2022-38326 Tenda AC15 WiFi Router V15.03.05.19_multi and AC18 WiFi Router V15.03.05.19_multi were discovered to contain a buffer overflow via the page parameter at /goform/NatStaticSetting.
CVE-2022-38325 Tenda AC15 WiFi Router V15.03.05.19_multi and AC18 WiFi Router V15.03.05.19_multi were discovered to contain a buffer overflow via the filePath parameter at /goform/expandDlnaFile.
CVE-2022-38314 Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the urls parameter at /goform/saveParentControlInfo.
CVE-2022-38313 Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo.
CVE-2022-38312 Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind.
CVE-2022-38311 Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/PowerSaveSet.
CVE-2022-38310 Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg.
CVE-2022-38309 Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.
CVE-2022-37824 Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGusetBasic.
CVE-2022-37823 Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the list parameter in the function formSetVirtualSer.
CVE-2022-37822 Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the function fromSetRouteStatic.
CVE-2022-37821 Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the ProvinceCode parameter in the function formSetProvince.
CVE-2022-37820 Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the ddnsEn parameter in the function formSetSysToolDDNS.
CVE-2022-37819 Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the timezone parameter in the function fromSetSysTime.
CVE-2022-37818 Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the list parameter at the function formSetQosBand.
CVE-2022-37817 Tenda AX1803 v1.0.0.1 was discovered to contain a stack overflow via the function fromSetIpMacBind.
CVE-2022-37816 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromSetIpMacBind.
CVE-2022-37815 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the PPPOEPassword parameter in the function formQuickIndex.
CVE-2022-37814 Tenda AC1206 V15.03.06.23 was discovered to contain multiple stack overflows via the deviceMac and the device_id parameters in the function addWifiMacFilter.
CVE-2022-37813 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromSetSysTime.
CVE-2022-37812 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the firewallEn parameter in the function formSetFirewallCfg.
CVE-2022-37811 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the startIp parameter in the function formSetPPTPServer.
CVE-2022-37810 Tenda AC1206 V15.03.06.23 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.
CVE-2022-37809 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the speed_dir parameter in the function formSetSpeedWan.
CVE-2022-37808 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the index parameter in the function formWifiWpsOOB.
CVE-2022-37807 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function formSetClientState.
CVE-2022-37806 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromDhcpListClient.
CVE-2022-37805 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromWizardHandle.
CVE-2022-37804 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the time parameter in the function saveParentControlInfo.
CVE-2022-37803 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromAddressNat.
CVE-2022-37802 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromNatStaticSetting.
CVE-2022-37801 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function formSetQosBand.
CVE-2022-37800 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function fromSetRouteStatic.
CVE-2022-37799 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the time parameter at the function setSmartPowerManagement.
CVE-2022-37798 Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function formSetVirtualSer.
CVE-2022-37292 Tenda AX12 V22.03.01.21_CN is vulnerable to Buffer Overflow. This overflow is triggered in the sub_42FDE4 function, which satisfies the request of the upper-level interface function sub_430124, that is, handles the post request under /goform/SetIpMacBind.
CVE-2022-37176 Tenda AC6(AC1200) v5.0 Firmware v02.03.01.114 and below contains a vulnerability which allows attackers to remove the Wi-Fi password and force the device into open security mode via a crafted packet sent to goform/setWizard.
CVE-2022-37175 Tenda ac15 firmware V15.03.05.18 httpd server has stack buffer overflow in /goform/formWifiBasicSet.
CVE-2022-36587 In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, there is a buffer overflow vulnerability caused by sprintf in function in the httpd binary.
CVE-2022-36586 In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, there is a buffer overflow vulnerability caused by strcpy in function 0x869f4 in the httpd binary.
CVE-2022-36585 In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, in httpd binary, the addDhcpRule function has a buffer overflow caused by sscanf.
CVE-2022-36584 In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, the getsinglepppuser function has a buffer overflow caused by sscanf.
CVE-2022-36571 Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting.
CVE-2022-36570 Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg.
CVE-2022-36569 Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg.
CVE-2022-36568 Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList.
CVE-2022-36552 Tenda AC6(AC1200) v5.0 Firmware v02.03.01.114 and below contains an issue in the component /cgi-bin/DownloadFlash which allows attackers to steal all data such as source code and system files via a crafted GET request.
CVE-2022-36273 Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg.
CVE-2022-36233 Tenda AC9 V15.03.2.13 is vulnerable to Buffer Overflow via httpd, form_fast_setting_wifi_set. httpd.
CVE-2022-35561 A stack overflow vulnerability exists in /goform/WifiMacFilterSet in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter.
CVE-2022-35560 A stack overflow vulnerability exists in /goform/wifiSSIDset in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter.
CVE-2022-35559 A stack overflow vulnerability exists in /goform/setAutoPing in Tenda W6 V1.0.0.9(4122), which allows an attacker to construct ping1 parameters and ping2 parameters for a stack overflow attack. An attacker can use this vulnerability to execute arbitrary code execution.
CVE-2022-35558 A stack overflow vulnerability exists in /goform/WifiMacFilterGet in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter.
CVE-2022-35557 A stack overflow vulnerability exists in /goform/wifiSSIDget in Tenda W6 V1.0.0.9(4122) version, which can be exploited by attackers to cause a denial of service (DoS) via the index parameter.
CVE-2022-35555 A command injection vulnerability exists in /goform/exeCommand in Tenda W6 V1.0.0.9(4122), which allows attackers to construct cmdinput parameters for arbitrary command execution.
CVE-2022-35201 Tenda-AC18 V15.03.05.05 was discovered to contain a remote command execution (RCE) vulnerability.
CVE-2022-34597 Tenda AX1806 v1.0.0.1 was discovered to contain a command injection vulnerability via the function WanParameterSetting.
CVE-2022-34596 Tenda AX1803 v1.0.0.1_2890 was discovered to contain a command injection vulnerability via the function WanParameterSetting.
CVE-2022-34595 Tenda AX1803 v1.0.0.1_2890 was discovered to contain a command injection vulnerability via the function setipv6status.
CVE-2022-32386 Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan.
CVE-2022-32385 Tenda AC23 v16.03.07.44 is vulnerable to Stack Overflow that will allow for the execution of arbitrary code (remote).
CVE-2022-32384 Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the security_5g parameter in the function formWifiBasicSet.
CVE-2022-32383 Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the AdvSetMacMtuWan function.
CVE-2022-32054 Tenda AC10 US_AC10V1.0RTL_V15.03.06.26_multi_TD01 was discovered to contain a remote code execution (RCE) vulnerability via the lanIp parameter.
CVE-2022-32043 Tenda M3 V1.0.0.12 was discovered to contain a stack overflow via the function formSetAccessCodeInfo.
CVE-2022-32041 Tenda M3 V1.0.0.12 was discovered to contain a stack overflow via the function formGetPassengerAnalyseData.
CVE-2022-32040 Tenda M3 V1.0.0.12 was discovered to contain a stack overflow via the function formSetCfm.
CVE-2022-32039 Tenda M3 V1.0.0.12 was discovered to contain a stack overflow via the listN parameter in the function fromDhcpListClient.
CVE-2022-32037 Tenda M3 V1.0.0.12 was discovered to contain a stack overflow via the function formSetAPCfg.
CVE-2022-32036 Tenda M3 V1.0.0.12 was discovered to contain multiple stack overflow vulnerabilities via the ssidList, storeName, and trademark parameters in the function formSetStoreWeb.
CVE-2022-32035 Tenda M3 V1.0.0.12 was discovered to contain a stack overflow via the function formMasterMng.
CVE-2022-32034 Tenda M3 V1.0.0.12 was discovered to contain a stack overflow via the items parameter in the function formdelMasteraclist.
CVE-2022-32033 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow via the function formSetVirtualSer.
CVE-2022-32032 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow via the deviceList parameter in the function formAddMacfilterRule.
CVE-2022-32031 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow via the list parameter in the function fromSetRouteStatic.
CVE-2022-32030 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow via the list parameter in the function formSetQosBand.
CVE-2022-31446 Tenda AC18 router V15.03.05.19 and V15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac.
CVE-2022-30477 Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetClientState request.
CVE-2022-30476 Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetFirewallCfg request.
CVE-2022-30475 Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/WifiExtraSet request.
CVE-2022-30474 Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a heap overflow in the httpd module when handling /goform/saveParentControlInfo request.
CVE-2022-30473 Tenda AC Series Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function form_fast_setting_wifi_set
CVE-2022-30472 Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat
CVE-2022-30425 Tenda Technology Co.,Ltd HG6 3.3.0-210926 was discovered to contain a command injection vulnerability via the pingAddr and traceAddr parameters. This vulnerability is exploited via a crafted POST request.
CVE-2022-30040 Tenda AX1803 v1.0.0.1_2890 is vulnerable to Buffer Overflow. The vulnerability lies in rootfs_ In / goform / setsystimecfg of / bin / tdhttpd in ubif file system, attackers can access http://ip/goform/SetSysTimeCfg, and by setting the ntpserve parameter, the stack buffer overflow can be caused to achieve the effect of router denial of service.
CVE-2022-30033 Tenda TX9 Pro V22.03.02.10 is vulnerable to Buffer Overflow via the functtion setIPv6Status() in httpd module.
CVE-2022-30023 Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function.
CVE-2022-29592 Tenda TX9 Pro 22.03.02.10 devices allow OS command injection via set_route (called by doSystemCmd_route).
CVE-2022-29591 Tenda TX9 Pro 22.03.02.10 devices have a SetNetControlList buffer overflow.
CVE-2022-28973 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow via the wanMTU parameter in the function fromAdvSetMacMtuWan. This vulnerability allows attackers to cause a Denial of Service (DoS).
CVE-2022-28972 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow via the timeZone parameter in the function form_fast_setting_wifi_set. This vulnerability allows attackers to cause a Denial of Service (DoS).
CVE-2022-28971 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow via the list parameter in the function fromSetIpMacBind. This vulnerability allows attackers to cause a Denial of Service (DoS).
CVE-2022-28970 Tenda AX1806 v1.0.0.1 was discovered to contain a heap overflow via the mac parameter in the function GetParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS).
CVE-2022-28969 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGusetBasic. This vulnerability allows attackers to cause a Denial of Service (DoS).
CVE-2022-28917 Tenda AX12 v22.03.01.21_cn was discovered to contain a stack overflow via the lanIp parameter in /goform/AdvSetLanIp.
CVE-2022-28572 Tenda AX1806 v1.0.0.1 was discovered to contain a command injection vulnerability in `SetIPv6Status` function
CVE-2022-28561 There is a stack overflow vulnerability in the /goform/setMacFilterCfg function in the httpd service of Tenda ax12 22.03.01.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload
CVE-2022-28560 There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload
CVE-2022-28557 There is a command injection vulnerability at the /goform/setsambacfg interface of Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin device web, which can also cooperate with CVE-2021-44971 to cause unconditional arbitrary command execution
CVE-2022-28556 Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971
CVE-2022-28082 Tenda AX12 v22.03.01.21_CN was discovered to contain a stack overflow via the list parameter at /goform/SetNetControlList.
CVE-2022-27375 Tenda AX12 V22.03.01.21_CN was discovered to contain a Cross-Site Request Forgery (CSRF) via the function sub_422168 at /goform/WifiExtraSet.
CVE-2022-27374 Tenda AX12 V22.03.01.21_CN was discovered to contain a Cross-Site Request Forgery (CSRF) via the function sub_42E328 at /goform/SysToolReboot.
CVE-2022-27083 Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /cgi-bin/uploadAccessCodePic.
CVE-2022-27082 Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/SetInternetLanInfo.
CVE-2022-27081 Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/SetLanInfo.
CVE-2022-27080 Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/setWorkmode.
CVE-2022-27079 Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/setPicListItem.
CVE-2022-27078 Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/setAdInfoDetail.
CVE-2022-27077 Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /cgi-bin/uploadWeiXinPic.
CVE-2022-27076 Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/delAd.
CVE-2022-27022 There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload.
CVE-2022-27016 There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn.
CVE-2022-26536 Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/setFixTools.
CVE-2022-26290 Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/WriteFacMac.
CVE-2022-26289 Tenda M3 1.10 V1.0.0.12(4856) was discovered to contain a command injection vulnerability via the component /goform/exeCommand.
CVE-2022-26278 Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function.
CVE-2022-26243 Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow in the setSmartPowerManagement function.
CVE-2022-25566 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via the time parameter.
CVE-2022-25561 Tenda AX12 v22.03.01.21 was discovered to contain a stack overflow in the function sub_42DE00. This vulnerability allows attackers to cause a Denial of Service (DoS) via the list parameter.
CVE-2022-25560 Tenda AX12 v22.03.01.21 was discovered to contain a stack overflow in the function sub_4327CC. This vulnerability allows attackers to cause a Denial of Service (DoS) via the list parameter.
CVE-2022-25558 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function formSetProvince. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ProvinceCode parameter.
CVE-2022-25557 Tenda AX1806 v1.0.0.1 was discovered to contain a heap overflow in the function saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via the urls parameter.
CVE-2022-25556 Tenda AX12 v22.03.01.21 was discovered to contain a stack overflow in the function sub_42E328. This vulnerability allows attackers to cause a Denial of Service (DoS) via the list parameter.
CVE-2022-25555 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function fromSetSysTime. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ntpServer parameter.
CVE-2022-25554 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via the deviceId parameter.
CVE-2022-25553 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function formSetSysToolDDNS. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ddnsPwd parameter.
CVE-2022-25552 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function form_fast_setting_wifi_set. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ssid parameter.
CVE-2022-25551 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function formSetSysToolDDNS. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ddnsDomain parameter.
CVE-2022-25550 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via the deviceName parameter.
CVE-2022-25549 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function formSetSysToolDDNS. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ddnsEn parameter.
CVE-2022-25548 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function fromSetSysTime. This vulnerability allows attackers to cause a Denial of Service (DoS) via the serverName parameter.
CVE-2022-25547 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function fromSetSysTime. This vulnerability allows attackers to cause a Denial of Service (DoS) via the time parameter.
CVE-2022-25546 Tenda AX1806 v1.0.0.1 was discovered to contain a stack overflow in the function formSetSysToolDDNS. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ddnsUser parameter.
CVE-2022-25461 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the startip parameter in the SetPptpServerCfg function.
CVE-2022-25460 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the endip parameter in the SetPptpServerCfg function.
CVE-2022-25459 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the S1 parameter in the SetSysTimeCfg function.
CVE-2022-25458 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the cmdinput parameter in the exeCommand function.
CVE-2022-25457 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function.
CVE-2022-25456 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the security_5g parameter in the WifiBasicSet function.
CVE-2022-25455 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function.
CVE-2022-25454 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the loginpwd parameter in the SetFirewallCfg function.
CVE-2022-25453 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the time parameter in the saveParentControlInfo function.
CVE-2022-25452 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the URLs parameter in the saveParentControlInfo function.
CVE-2022-25451 Tenda AC6 V15.03.05.09_multi was discovered to contain a stack overflow via the list parameter in the setstaticroutecfg function.
CVE-2022-25450 Tenda AC6 V15.03.05.09_multi was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function.
CVE-2022-25449 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function.
CVE-2022-25448 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the day parameter in the openSchedWifi function.
CVE-2022-25447 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function.
CVE-2022-25446 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the schedstarttime parameter in the openSchedWifi function.
CVE-2022-25445 Tenda AC6 v15.03.05.09_multi was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function.
CVE-2022-25441 Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function.
CVE-2022-25440 Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function.
CVE-2022-25439 Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function.
CVE-2022-25438 Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function.
CVE-2022-25437 Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function.
CVE-2022-25435 Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function.
CVE-2022-25434 Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function.
CVE-2022-25433 Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function.
CVE-2022-25431 Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function.
CVE-2022-25429 Tenda AC9 v15.03.2.21 was discovered to contain a buffer overflow via the time parameter in the saveparentcontrolinfo function.
CVE-2022-25428 Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the deviceId parameter in the saveparentcontrolinfo function.
CVE-2022-25427 Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the schedendtime parameter in the openSchedWifi function.
CVE-2022-25418 Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function openSchedWifi.
CVE-2022-25417 Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the function saveparentcontrolinfo.
CVE-2022-25414 Tenda AC9 V15.03.2.21_cn was discovered to contain a stack overflow via the parameter NPTR.
CVE-2022-24995 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function fromSetSysTime. This vulnerability allows attackers to cause a Denial of Service (DoS) via the time parameter.
CVE-2022-24172 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formAddDhcpBindRule. This vulnerability allows attackers to cause a Denial of Service (DoS) via the addDhcpRules parameter.
CVE-2022-24171 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetPppoeServer. This vulnerability allows attackers to execute arbitrary commands via the pppoeServerIP, pppoeServerStartIP, and pppoeServerEndIP parameters.
CVE-2022-24170 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetIpSecTunnel. This vulnerability allows attackers to execute arbitrary commands via the IPsecLocalNet and IPsecRemoteNet parameters.
CVE-2022-24169 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formIPMacBindAdd. This vulnerability allows attackers to cause a Denial of Service (DoS) via the IPMacBindRule parameter.
CVE-2022-24168 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetIpGroup. This vulnerability allows attackers to execute arbitrary commands via the IPGroupStartIP and IPGroupEndIP parameters.
CVE-2022-24167 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetDMZ. This vulnerability allows attackers to execute arbitrary commands via the dmzHost1 parameter.
CVE-2022-24166 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formSetSysTime. This vulnerability allows attackers to cause a Denial of Service (DoS) via the manualTime parameter.
CVE-2022-24165 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetQvlanList. This vulnerability allows attackers to execute arbitrary commands via the qvlanIP parameter.
CVE-2022-24164 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formSetVirtualSer. This vulnerability allows attackers to cause a Denial of Service (DoS) via the DnsHijackRule parameter.
CVE-2022-24163 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function fromSetSysTime. This vulnerability allows attackers to cause a Denial of Service (DoS) via the timeZone parameter.
CVE-2022-24162 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function saveParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via the time parameter.
CVE-2022-24161 Tenda AX3 v16.03.12.10_CN was discovered to contain a heap overflow in the function GetParentControlInfo. This vulnerability allows attackers to cause a Denial of Service (DoS) via the mac parameter.
CVE-2022-24160 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formSetDeviceName. This vulnerability allows attackers to cause a Denial of Service (DoS) via the devName parameter.
CVE-2022-24159 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formSetPPTPServer. This vulnerability allows attackers to cause a Denial of Service (DoS) via the startIp and endIp parameters.
CVE-2022-24158 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function fromSetIpMacBind. This vulnerability allows attackers to cause a Denial of Service (DoS) via the list parameter.
CVE-2022-24157 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formSetMacFilterCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via the deviceList parameter.
CVE-2022-24156 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formSetVirtualSer. This vulnerability allows attackers to cause a Denial of Service (DoS) via the list parameter.
CVE-2022-24155 Tenda AX3 v16.03.12.10_CN was discovered to contain a heap overflow in the function setSchedWifi. This vulnerability allows attackers to cause a Denial of Service (DoS) via the schedStartTime and schedEndTime parameters.
CVE-2022-24154 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formSetRebootTimer. This vulnerability allows attackers to cause a Denial of Service (DoS) via the rebootTime parameter.
CVE-2022-24153 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formAddMacfilterRule. This vulnerability allows attackers to cause a Denial of Service (DoS) via the devName parameter.
CVE-2022-24152 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function fromSetRouteStatic. This vulnerability allows attackers to cause a Denial of Service (DoS) via the list parameter.
CVE-2022-24151 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function fromSetWifiGusetBasic. This vulnerability allows attackers to cause a Denial of Service (DoS) via the shareSpeed parameter.
CVE-2022-24150 Tenda AX3 v16.03.12.10_CN was discovered to contain a command injection vulnerability in the function formSetSafeWanWebMan. This vulnerability allows attackers to execute arbitrary commands via the remoteIp parameter.
CVE-2022-24149 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function fromSetWirelessRepeat. This vulnerability allows attackers to cause a Denial of Service (DoS) via the wpapsk_crypto parameter.
CVE-2022-24148 Tenda AX3 v16.03.12.10_CN was discovered to contain a command injection vulnerability in the function mDMZSetCfg. This vulnerability allows attackers to execute arbitrary commands via the dmzIp parameter.
CVE-2022-24147 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function fromAdvSetMacMtuWan. This vulnerability allows attackers to cause a Denial of Service (DoS) via the wanMTU, wanSpeed, cloneType, mac, and serviceName parameters.
CVE-2022-24146 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formSetQosBand. This vulnerability allows attackers to cause a Denial of Service (DoS) via the list parameter.
CVE-2022-24145 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formWifiBasicSet. This vulnerability allows attackers to cause a Denial of Service (DoS) via the security and security_5g parameters.
CVE-2022-24144 Tenda AX3 v16.03.12.10_CN was discovered to contain a command injection vulnerability in the function WanParameterSetting. This vulnerability allows attackers to execute arbitrary commands via the gateway, dns1, and dns2 parameters.
CVE-2022-24143 Tenda AX3 v16.03.12.10_CN and AX12 22.03.01.2_CN was discovered to contain a stack overflow in the function form_fast_setting_wifi_set. This vulnerability allows attackers to cause a Denial of Service (DoS) via the timeZone parameter.
CVE-2022-24142 Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function formSetFirewallCfg. This vulnerability allows attackers to cause a Denial of Service (DoS) via the firewallEn parameter.
CVE-2021-46408 Tenda AX12 v22.03.01.21 was discovered to contain a stack buffer overflow in the function sub_422CE4. This vulnerability allows attackers to cause a Denial of Service (DoS) via the strcpy parameter.
CVE-2021-46394 There is a stack buffer overflow vulnerability in the formSetPPTPServer function of Tenda-AX3 router V16.03.12.10_CN. The v13 variable is directly retrieved from the http request parameter startIp. Then v13 will be splice to stack by function sscanf without any security check, which causes stack overflow. By POSTing the page /goform/SetPptpServerCfg with proper startIp, the attacker can easily perform remote code execution with carefully crafted overflow data.
CVE-2021-46393 There is a stack buffer overflow vulnerability in the formSetPPTPServer function of Tenda-AX3 router V16.03.12.10_CN. The v10 variable is directly retrieved from the http request parameter startIp. Then v10 will be splice to stack by function sscanf without any security check,which causes stack overflow. By POSTing the page /goform/SetPptpServerCfg with proper startIp, the attacker can easily perform remote code execution with carefully crafted overflow data.
CVE-2021-46321 Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
CVE-2021-46265 Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wanBasicCfg module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
CVE-2021-46264 Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the onlineList module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
CVE-2021-46263 Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the wifiTime module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
CVE-2021-46262 Tenda AC Series Router AC11_V02.03.01.104_CN was discovered to contain a stack buffer overflow in the PPPoE module. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
CVE-2021-45997 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formSetPortMapping. This vulnerability allows attackers to cause a Denial of Service (DoS) via the portMappingServer, portMappingProtocol, portMappingWan, porMappingtInternal, and portMappingExternal parameters.
CVE-2021-45996 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formSetPortMapping. This vulnerability allows attackers to cause a Denial of Service (DoS) via the portMappingServer, portMappingProtocol, portMappingWan, porMappingtInternal, and portMappingExternal parameters.
CVE-2021-45995 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formSetStaticRoute. This vulnerability allows attackers to cause a Denial of Service (DoS) via the staticRouteNet, staticRouteMask, and staticRouteGateway parameters.
CVE-2021-45994 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formDelDhcpRule. This vulnerability allows attackers to cause a Denial of Service (DoS) via the delDhcpIndex parameter.
CVE-2021-45993 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formIPMacBindModify. This vulnerability allows attackers to cause a Denial of Service (DoS) via the IPMacBindRuleIP and IPMacBindRuleMac parameters.
CVE-2021-45992 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formSetQvlanList. This vulnerability allows attackers to cause a Denial of Service (DoS) via the qvlanName parameter.
CVE-2021-45991 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formAddVpnUsers. This vulnerability allows attackers to cause a Denial of Service (DoS) via the vpnUsers parameter.
CVE-2021-45990 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function uploadPicture. This vulnerability allows attackers to execute arbitrary commands via the pic_name parameter.
CVE-2021-45989 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function guestWifiRuleRefresh. This vulnerability allows attackers to cause a Denial of Service (DoS) via the qosGuestUpstream and qosGuestDownstream parameters.
CVE-2021-45988 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a stack overflow in the function formAddDnsForward. This vulnerability allows attackers to cause a Denial of Service (DoS) via the DnsForwardRule parameter.
CVE-2021-45987 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetNetCheckTools. This vulnerability allows attackers to execute arbitrary commands via the hostName parameter.
CVE-2021-45986 Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetUSBShareInfo. This vulnerability allows attackers to execute arbitrary commands via the usbOrdinaryUserName parameter.
CVE-2021-45608 Certain D-Link, Edimax, NETGEAR, TP-Link, Tenda, and Western Digital devices are affected by an integer overflow by an unauthenticated attacker. Remote code execution from the WAN interface (TCP port 20005) cannot be ruled out; however, exploitability was judged to be of "rather significant complexity" but not "impossible." The overflow is in SoftwareBus_dispatchNormalEPMsgOut in the KCodes NetUSB kernel module. Affected NETGEAR devices are D7800 before 1.0.1.68, R6400v2 before 1.0.4.122, and R6700v3 before 1.0.4.122.
CVE-2021-45401 A Command injection vulnerability exists in Tenda AC10U AC1200 Smart Dual-band Wireless Router AC10U V1.0 Firmware V15.03.06.49_multi via the setUsbUnload functionality. The vulnerability is caused because the client controlled "deviceName" value is passed directly to the "doSystemCmd" function.
CVE-2021-45392 A Buffer Overflow vulnerability exists in Tenda Router AX12 V22.03.01.21_CN in the sub_422CE4 function in page /goform/setIPv6Status via the prefixDelegate parameter, which causes a Denial of Service.
CVE-2021-45391 A Buffer Overflow vulnerability exists in Tenda Router AX12 V22.03.01.21_CN in the sub_422CE4 function in the goform/setIPv6Status binary file /usr/sbin/httpd via the conType parameter, which causes a Denial of Service.
CVE-2021-44971 Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE.
CVE-2021-44352 A Stack-based Buffer Overflow vulnerability exists in the Tenda AC15 V15.03.05.18_multi device via the list parameter in a post request in goform/SetIpMacBind.
CVE-2021-42659 There is a buffer overflow vulnerability in the Web server httpd of the router in Tenda router devices such as Tenda AC9 V1.0 V15.03.02.19(6318) and Tenda AC9 V3.0 V15.03.06.42_multi. When setting the virtual service, the httpd program will crash and exit when the super-long list parameter occurs.
CVE-2021-40546 Tenda AC6 US_AC6V4.0RTL_V02.03.01.26_cn.bin allows attackers (who have the administrator password) to cause a denial of service (device crash) via a long string in the wifiPwd_5G parameter to /goform/setWifi.
CVE-2021-38772 Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function.
CVE-2021-38278 Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the urls parameter in the saveParentControlInfo function.
CVE-2021-3186 A Stored Cross-site scripting (XSS) vulnerability in /main.html Wifi Settings in Tenda AC5 AC1200 version V15.03.06.47_multi allows remote attackers to inject arbitrary web script or HTML via the Wifi Name parameter.
CVE-2021-31758 An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setportList allows attackers to execute arbitrary code on the system via a crafted post request.
CVE-2021-31757 An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setVLAN allows attackers to execute arbitrary code on the system via a crafted post request.
CVE-2021-31756 An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /gofrom/setwanType allows attackers to execute arbitrary code on the system via a crafted post request. This occurs when input vector controlled by malicious attack get copied to the stack variable.
CVE-2021-31755 An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request.
CVE-2021-31627 Buffer Overflow vulnerability in Tenda AC9 V1.0 through V15.03.05.19(6318), and AC9 V3.0 V15.03.06.42_multi, allows attackers to execute arbitrary code via the index parameter.
CVE-2021-31624 Buffer Overflow vulnerability in Tenda AC9 V1.0 through V15.03.05.19(6318), and AC9 V3.0 V15.03.06.42_multi, allows attackers to execute arbitrary code via the urls parameter.
CVE-2021-27707 Buffer Overflow in Tenda G1 and G3 routers with firmware v15.11.0.17(9502)_CN allows remote attackers to execute arbitrary code via a crafted action/"portMappingIndex "request. This occurs because the "formDelPortMapping" function directly passes the parameter "portMappingIndex" to strcpy without limit.
CVE-2021-27706 Buffer Overflow in Tenda G1 and G3 routers with firmware version V15.11.0.17(9502)_CN allows remote attackers to execute arbitrary code via a crafted action/"IPMacBindIndex "request. This occurs because the "formIPMacBindDel" function directly passes the parameter "IPMacBindIndex" to strcpy without limit.
CVE-2021-27705 Buffer Overflow in Tenda G1 and G3 routers with firmware v15.11.0.17(9502)_CN allows remote attackers to execute arbitrary code via a crafted action/"qosIndex "request. This occurs because the "formQOSRuleDel" function directly passes the parameter "qosIndex" to strcpy without limit.
CVE-2021-27692 Command Injection in Tenda G1 and G3 routers with firmware versions v15.11.0.17(9502)_CN or v15.11.0.16(9024)_CN allows remote attackers to execute arbitrary OS commands via a crafted "action/umountUSBPartition" request. This occurs because the "formSetUSBPartitionUmount" function executes the "doSystemCmd" function with untrusted input.
CVE-2021-27691 Command Injection in Tenda G0 routers with firmware versions v15.11.0.6(9039)_CN and v15.11.0.5(5876)_CN , and Tenda G1 and G3 routers with firmware versions v15.11.0.17(9502)_CN or v15.11.0.16(9024)_CN allows remote attackers to execute arbitrary OS commands via a crafted action/setDebugCfg request. This occurs because the "formSetDebugCfg" function executes glibc's system function with untrusted input.
CVE-2020-35391 Tenda N300 F3 12.01.01.48 devices allow remote attackers to obtain sensitive information (possibly including an http_passwd line) via a direct request for cgi-bin/DownloadCfg/RouterCfm.cfg, a related issue to CVE-2017-14942. NOTE: the vulnerability report may suggest that either a ? character must be placed after the RouterCfm.cfg filename, or that the HTTP request headers must be unusual, but it is not known why these are relevant to the device's HTTP response behavior.
CVE-2020-28095 On Tenda AC1200 (Model AC6) 15.03.06.51_multi devices, a large HTTP POST request sent to the change password API will trigger the router to crash and enter an infinite boot loop.
CVE-2020-28094 On Tenda AC1200 (Model AC6) 15.03.06.51_multi devices, the default settings for the router speed test contain links to download malware named elive or CNKI E-Learning.
CVE-2020-28093 On Tenda AC1200 (Model AC6) 15.03.06.51_multi devices, admin, support, user, and nobody have a password of 1234.
CVE-2020-26728 A vulnerability was discovered in Tenda AC9 v3.0 V15.03.06.42_multi and Tenda AC9 V1.0 V15.03.05.19(6318)_CN which allows for remote code execution via shell metacharacters in the guestuser field to the __fastcall function with a POST request.
CVE-2020-24987 Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to "radius".
CVE-2020-22079 Stack-based buffer overflow in Tenda AC-10U AC1200 Router US_AC10UV1.0RTL_V15.03.06.48_multi_TDE01 allows remote attackers to execute arbitrary code via the timeZone parameter to goform/SetSysTimeCfg.
CVE-2020-20746 A stack-based buffer overflow in the httpd server on Tenda AC9 V15.03.06.60_EN allows remote attackers to execute arbitrary code or cause a denial of service (DoS) via a crafted POST request to /goform/SetStaticRouteCfg.
CVE-2020-15916 goform/AdvSetLanip endpoint on Tenda AC15 AC1900 15.03.05.19 devices allows remote attackers to execute arbitrary system commands via shell metacharacters in the lanIp POST parameter.
CVE-2020-13394 An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/SetNetControlList list parameter for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.
CVE-2020-13393 An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/saveParentControlInfo deviceId and time parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.
CVE-2020-13392 An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/setcfm funcpara1 parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.
CVE-2020-13391 An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/SetSpeedWan speed_dir parameter for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.
CVE-2020-13390 An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/addressNat entrys and mitInterface parameters for a POST request, a value is directly used in a sprintf to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.
CVE-2020-13389 An issue was discovered on Tenda AC6 V1.0 V15.03.05.19_multi_TD01, AC9 V1.0 V15.03.05.19(6318)_CN, AC9 V3.0 V15.03.06.42_multi, AC15 V1.0 V15.03.05.19_multi_TD01, and AC18 V15.03.05.19(6318_)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the /goform/openSchedWifi schedStartTime and schedEndTime parameters for a POST request, a value is directly used in a strcpy to a local variable placed on the stack, which overwrites the return address of a function. An attacker can construct a payload to carry out arbitrary code execution attacks.
CVE-2020-10989 An XSS issue in the /goform/WifiBasicSet endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute malicious payloads via the WifiName POST parameter.
CVE-2020-10988 A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
CVE-2020-10987 The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter.
CVE-2020-10986 A CSRF issue in the /goform/SysToolReboot endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to reboot the device and cause denial of service via a payload hosted by an attacker-controlled web page.
CVE-2019-5072 An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS2 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability.
CVE-2019-5071 An exploitable command injection vulnerability exists in the /goform/WanParameterSetting functionality of Tenda AC9 Router AC1200 Smart Dual-Band Gigabit WiFi Route (AC9V1.0 Firmware V15.03.05.16multiTRU). A specially crafted HTTP POST request can cause a command injection in the DNS1 post parameters, resulting in code execution. An attacker can send HTTP POST request with command to trigger this vulnerability.
CVE-2019-19506 Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a denial of service, caused by an error in the "homeplugd" process. By sending a specially crafted UDP packet, an attacker could exploit this vulnerability to cause the device to reboot.
CVE-2019-19505 Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the "Wireless" section in the web-UI. By sending a specially crafted hostname, a remote attacker could overflow a buffer and execute arbitrary code on the system or cause the application to crash.
CVE-2019-16412 In goform/setSysTools on Tenda N301 wireless routers, attackers can trigger a device crash via a zero wanMTU value. (Prohibition of this zero value is only enforced within the GUI.)
CVE-2019-16288 On Tenda N301 wireless routers, a long string in the wifiSSID parameter of a goform/setWifi POST request causes the device to crash.
CVE-2019-16213 Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 could allow a remote authenticated attacker to execute arbitrary commands on the system. By sending a specially crafted string, an attacker could modify the device name of an attached PLC adapter to inject and execute arbitrary commands on the system with root privileges.
CVE-2018-7561 Stack-based Buffer Overflow in httpd on Tenda AC9 devices V15.03.05.14_EN allows remote attackers to cause a denial of service or possibly have unspecified other impact.
CVE-2018-5770 An issue was discovered on Tenda AC15 devices. A remote, unauthenticated attacker can make a request to /goform/telnet, creating a telnetd service on the device. This service is password protected; however, several default accounts exist on the device that are root accounts, which can be used to log in.
CVE-2018-5768 A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
CVE-2018-5767 An issue was discovered on Tenda AC15 V15.03.1.16_multi devices. A remote, unauthenticated attacker can gain remote code execution on the device with a crafted password parameter for the COOKIE header.
CVE-2018-20373 Tenda ADSL modem routers 1.0.1 allow XSS via the hostname of a DHCP client.
CVE-2018-18732 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'ntpServer' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-18731 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-18730 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-18729 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow.
CVE-2018-18728 An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. They allow remote code execution via shell metacharacters in the usbName field to the __fastcall function with a POST request.
CVE-2018-18727 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-18709 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-18708 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-18707 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-18706 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
CVE-2018-16334 An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN devices. The mac parameter in a POST request is used directly in a doSystemCmd call, causing OS command injection.
CVE-2018-16333 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow.
CVE-2018-14559 An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow.
CVE-2018-14558 An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
CVE-2018-14557 An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow.
CVE-2018-14497 Tenda D152 ADSL routers allow XSS via a crafted SSID.
CVE-2018-14492 Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through V15.03.06.23_CN devices have a Stack-based Buffer Overflow via a long limitSpeed or limitSpeedup parameter to an unspecified /goform URI.
CVE-2017-9139 There is a stack-based buffer overflow on some Tenda routers (FH1202/F1202/F1200: versions before 1.2.0.20). Crafted POST requests to an unspecified URL result in DoS, interrupting the HTTP service (used to login to the web UI of a router) for 1 to 2 seconds.
CVE-2017-9138 There is a debug-interface vulnerability on some Tenda routers (FH1202/F1202/F1200: versions before 1.2.0.20). After connecting locally to a router in a wired or wireless manner, one can bypass intended access restrictions by sending shell commands directly and reading their results, or by entering shell commands that change this router's username and password.
CVE-2017-16936 Directory Traversal vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to read arbitrary files via a cgi-bin/luci/request?op=1&path= URI that uses directory traversal sequences after a /usb/ substring.
CVE-2017-16923 Command Injection vulnerability in app_data_center on Shenzhen Tenda Ac9 US_AC9V1.0BR_V15.03.05.14_multi_TD01, Ac9 ac9_kf_V15.03.05.19(6318_)_cn, Ac15 US_AC15V1.0BR_V15.03.05.18_multi_TD01, Ac15 US_AC15V1.0BR_V15.03.05.19_multi_TD01, Ac18 US_AC18V1.0BR_V15.03.05.05_multi_TD01, and Ac18 ac18_kf_V15.03.05.19(6318_)_cn devices allows remote unauthenticated attackers to execute arbitrary OS commands via a crafted cgi-bin/luci/usbeject?dev_name= GET request from the LAN. This occurs because the "sub_A6E8 usbeject_process_entry" function executes a system function with untrusted input.
CVE-2017-14515 Heap-based Buffer Overflow on Tenda W15E devices before 15.11.0.14 allows remote attackers to cause a denial of service (temporary HTTP outage and forced logout) via unspecified vectors.
CVE-2017-14514 Directory Traversal on Tenda W15E devices before 15.11.0.14 allows remote attackers to read unencrypted files via a crafted URL.
CVE-2015-5996 Cross-site request forgery (CSRF) vulnerability on Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 allows remote attackers to hijack the authentication of arbitrary users.
CVE-2015-5995 Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attackers to obtain administrative access via a certain admin substring in an HTTP Cookie header.
CVE-2015-5994 The web management interface on Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 has a default password of admin for the admin account and a default password of password for the medialink account, which allows remote attackers to obtain administrative privileges by leveraging a Wi-Fi session.
CVE-2014-7281 Cross-site request forgery (CSRF) vulnerability in Shenzhen Tenda Technology Tenda A32 Router with firmware 5.07.53_CN allows remote attackers to hijack the authentication of administrators for requests that reboot the device via a request to goform/SysToolReboot.
CVE-2014-5246 The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication and gain administrator access by setting the admin:language cookie to zh-cn.
  
You can also search by reference using the CVE Reference Maps.
For More Information:  CVE Request Web Form (select “Other” from dropdown)